Skip to content

Existing buildings

Threshold Building Inspections

A building over three stories or fifty feet answers the county with a fuller file: a structural engineer with the state’s specialization — a self-qualification letter in Miami-Dade, a Special Inspector’s licence in Broward — and the façade looked at as well.

Coverage
Miami-Dade & Broward County, Florida

In plain words

What is a threshold building inspection?

  1. 01 What it is

    The county inspection of a building over three stories or fifty feet, with the fuller file its size requires.

  2. 02 Who it is for

    Towers, mid-rises past the third story, hotels, tall garages and large assembly halls in Miami-Dade and Broward.

  3. 03 What you get

    The structural report from a qualified structural engineer, the electrical report, and the façade review where it applies.

Read the full explanation

Miami-Dade and Broward run the same inspection programs for every aging building, but a threshold building — more than three stories or fifty feet, or a large assembly space — is held to more: its structural report has to come from a structural engineer with the state’s structural specialization — with a self-qualification letter in Miami-Dade, licensed as a Special Inspector in Broward — and a façade of structural glazing has an inspection of its own. The rule is easiest to meet before the report is written.

  • 01The county’s notice names a building over three stories or fifty feet, or a large assembly space.
  • 02A report filed for a threshold building came back for the structural engineer’s qualification, or for a self-qualification letter Miami-Dade did not find in it.
  • 03The façade carries structural sealant glazing and its own inspection is due.

Condominium and cooperative boards of buildings over three stories · Owners and managers of towers, parking structures and large assembly buildings · Property managers handling a notice for a threshold building

The threshold, in numbers

  1. 3 stories

    More than three, whatever the building is used for

  2. 50 feet

    Or taller than fifty feet

  3. 500 people

    Or an assembly space over 5,000 sq ft, at any height

  4. 5 years

    The cycle of a façade of structural glazing

Buildings past the threshold

Height or a crowd makes the threshold.

Whatever it is used for, a building crosses the threshold past three stories or fifty feet, and at any height when it holds an assembly space over 5,000 sq ft for more than 500 people: residential towers, taller mid-rises, office towers, hotels, tall garages and the halls where people gather.

  • Residential towers

  • Mid-rises past the third story

  • Office towers

  • Hotels

  • Parking garages over fifty feet

  • Churches, auditoriums & arenas

What's included

  • 01 Is it a threshold building?

    Height and use decide whether the building is a threshold building and what its report must carry; glazing decides whether the façade is inspected too.

  • 02 Structural inspection

    The inspection and its report follow each county’s rules for a threshold building; in Miami-Dade, the self-qualification letter goes with the report.

  • 03 Electrical inspection

    The building’s electrical systems are inspected on site and reported on the county’s own form.

  • 04 Façade & glazing

    A façade of structural glazing is reviewed too; in Miami-Dade it is inspected on a cycle of its own.

The full scope, line by line
  1. Which program and which report the building owes: recertification, the Building Safety Inspection Program, or the milestone inspection they satisfy
  2. Structural inspection and report by a structural engineer who meets the counties’ requirements for threshold buildings, with the self-qualification letter in Miami-Dade
  3. Electrical inspection and report by an engineer of the electrical discipline
  4. Review of the façade and of structural sealant glazing where the building has it
  5. Repair scope for what the inspection finds, and the reinspection that closes the file
  6. Filing with the building official on the county’s forms

What you receive

  1. Structural report on the county’s form, with the self-qualification letter where Miami-Dade asks for it
  2. Electrical report on the county’s form
  3. Façade and structural glazing report where it applies
  4. Repair scope, and the reinspection that closes the file

Next step

Send the notice, or the address and the number of stories, and we tell you which program the building falls under and what its report has to carry.

How the work runs

01

Classify

The building’s height, occupancy and glazing decide the program, the report and who may prepare it.

02

Inspect

Structural and electrical inspections on site, and the façade where the building has structural glazing.

03

Report

The reports on the county’s forms — in Miami-Dade with the self-qualification letter attached — filed with the building official.

04

Close

Repair scope if anything is found, the reinspection, and the letter that closes the file.

What clients say

  • From the contractor’s side, clear inspection notes make a big difference. Their observations identified the locations and items that needed attention, so our superintendent could follow up with the right crew. We weren’t left guessing what the notes referred to.

    Ryan W.
  • Our construction schedule changed a couple of times, and we had to coordinate new inspection dates. We stayed in contact and worked out the visits around the updated schedule. I appreciated having someone who understood that things move around on an active job.

    Sergio C.
  • I handled the project paperwork. The inspection records were organized and easy to share with our construction team. That might sound like a small thing, but it saved me a lot of chasing documents.

    Allison R.

Questions & answers

Questions about threshold buildings

Is my building a threshold building?

If it has more than three stories or stands more than fifty feet tall, yes; so is a building with an assembly space over 5,000 square feet that holds more than 500 people. Miami-Dade applies the same rule to any building of four stories or more. Send the address and we confirm it.

Why was our report sent back?

Look first at who prepared it: the counties accept a threshold building’s structural report only from a structural engineer with the state’s structural specialization — in Miami-Dade with a self-qualification letter attached, in Broward from one who is also a licensed Special Inspector. We settle that before the report is written, while the clock is still running for you.

Does the façade need its own inspection?

In Miami-Dade, when it is structural sealant glazing, yes: the county asks for a façade report every five years, on its own cycle, separate from the program’s report. We tell you whether your façade falls under it.

Is this a different program from the recertification or the BSIP?

No. It is the same county program — recertification in Miami-Dade, the Building Safety Inspection Program in Broward, and the state’s milestone inspection they both satisfy — applied to a building that, by its size, owes a fuller file. The notice, the dates and the forms are the program’s; what changes is who may prepare the structural report and what travels with it.

Good to know

What makes a building a threshold building, and what that changes.

All 3 notes
  • A threshold building is more than three stories or fifty feet, or an assembly occupancy over 5,000 square feet and 500 people; Miami-Dade inspects any building of four stories or more the same way.
  • Both counties ask that the structural report of a threshold building come from a structural engineer with the state’s structural specialization — in Miami-Dade with a self-qualification letter, in Broward one also licensed as a Special Inspector; the electrical report, from a professional of the electrical discipline.
  • In Miami-Dade, a threshold building with a façade of structural sealant glazing has that façade inspected on its own cycle, every five years.

Contact

Get in touch.

Tell us about the building and what you need from us. Write in English or in Spanish.

Attachments optional

Photographs, drawings or reports. PDF, images, DWG, DXF or ZIP, up to 25 MB each, five files.